TVORNICA CEMENTA "SVETI JURAJ"

The coordinates of the location of the facility should be expressed in longitude and latitude coordinates giving a precision of the order of at least +/- 500 meters and referring to the geographical centre of the site of the facility.
National ID: 
The national Identification of the facility.
HR010292357
Report year: 
Reference year of the report file
2018

Main Economic Activity:

Product Name: 
The product/product group.
Cementni klinker
Product Quantity: 
The total volume.
830195.00
Total Employee Quantity: 
The number of employees.
307
Operation Hours: 
The number of operating hours in reporting year.
6964 hours
River Basin District: 
Adriatic [HRJ]
NUTS: 
HR035 [HR035]
Parent company name: 
Name of the parent company, i.e. the company that owns or controls the company operating the facility. Required unless confidentiality is claimed.
CEMEX HRVATSKA D.D.
Address: 
TVORNICA CEMENTA "SVETI JURAJ"
45
F. TUĐMANA
21212 Kaštel Sućurac
Competent Authority Party: 
Pollutant Release: 
PollutantMediumMethod BasisMethod Used TypeMethod Used DesignationTotal QuantityAccidental QuantityConfidential Indicator
Identifies the environmental medium (air, water, land).
Air
Measurement
Identifies the type of method used (CEN/ISO, ETS, etc.). Notice that the method type “WEIGH” (i.e. weighing) only is allowed for waste transfer.
Other measurement/calculation methodology
A short designation or description of the method used. Required for some method types as indicated in the list of legal method type codes.
HRN EN 14792:2007
Total quantity including accidental quantity [kg/year]. Values below threshold are considered voluntary and will not be published.
791000 kg/year
Accidental quantity [kg/year].
0 kg/year
Identifies the environmental medium (air, water, land).
Air
Measurement
Identifies the type of method used (CEN/ISO, ETS, etc.). Notice that the method type “WEIGH” (i.e. weighing) only is allowed for waste transfer.
Other measurement/calculation methodology
A short designation or description of the method used. Required for some method types as indicated in the list of legal method type codes.
HRN EN 15058:2008
Total quantity including accidental quantity [kg/year]. Values below threshold are considered voluntary and will not be published.
1720000 kg/year
Accidental quantity [kg/year].
0 kg/year
Identifies the environmental medium (air, water, land).
Air
Calculation
Identifies the type of method used (CEN/ISO, ETS, etc.). Notice that the method type “WEIGH” (i.e. weighing) only is allowed for waste transfer.
IPCC Guidelines
A short designation or description of the method used. Required for some method types as indicated in the list of legal method type codes.
EF - IPCC
Total quantity including accidental quantity [kg/year]. Values below threshold are considered voluntary and will not be published.
687000000 kg/year
Accidental quantity [kg/year].
0 kg/year
Identifies the environmental medium (air, water, land).
Air
Measurement
Identifies the type of method used (CEN/ISO, ETS, etc.). Notice that the method type “WEIGH” (i.e. weighing) only is allowed for waste transfer.
Other measurement/calculation methodology
A short designation or description of the method used. Required for some method types as indicated in the list of legal method type codes.
Ne postoji međunarodno priznata norma
Total quantity including accidental quantity [kg/year]. Values below threshold are considered voluntary and will not be published.
60600 kg/year
Accidental quantity [kg/year].
0 kg/year
Identifies the environmental medium (air, water, land).
Air
Measurement
Identifies the type of method used (CEN/ISO, ETS, etc.). Notice that the method type “WEIGH” (i.e. weighing) only is allowed for waste transfer.
Other measurement/calculation methodology
A short designation or description of the method used. Required for some method types as indicated in the list of legal method type codes.
HRN EN 14884:2008
Total quantity including accidental quantity [kg/year]. Values below threshold are considered voluntary and will not be published.
20 kg/year
Accidental quantity [kg/year].
0 kg/year
Identifies the environmental medium (air, water, land).
Air
Calculation
Identifies the type of method used (CEN/ISO, ETS, etc.). Notice that the method type “WEIGH” (i.e. weighing) only is allowed for waste transfer.
UNECE/EMEP EMEP/CORINAIR Emission Inventory Guidebook
A short designation or description of the method used. Required for some method types as indicated in the list of legal method type codes.
EF - EMEP/EEA
Total quantity including accidental quantity [kg/year]. Values below threshold are considered voluntary and will not be published.
2150 kg/year
Accidental quantity [kg/year].
0 kg/year
Waste Transfer: 
Waste typeWaste TreatmentQuantityMethod BasisMethod Used TypeMethod Used DesignationConfidential Indicator
Identifies the type of waste (non-hazardous, hazardous within country and hazardous outside country)
Hazardous waste within country
Identifies the waste treatment operation (recovery or disposal). Required unless confidentiality is claimed.
Destined for disposal
Quantity [t/year]. Required unless confidentiality is claimed
23.50 t/year
Measurement
Identifies the type of method used (CEN/ISO, ETS, etc.). Notice that the method type “WEIGH” (i.e. weighing) only is allowed for waste transfer.
Weighing
Identifies the type of waste (non-hazardous, hazardous within country and hazardous outside country)
Hazardous waste within country
Identifies the waste treatment operation (recovery or disposal). Required unless confidentiality is claimed.
Destined for recovery
Quantity [t/year]. Required unless confidentiality is claimed
1.51 t/year
Measurement
Identifies the type of method used (CEN/ISO, ETS, etc.). Notice that the method type “WEIGH” (i.e. weighing) only is allowed for waste transfer.
Weighing
Identifies the type of waste (non-hazardous, hazardous within country and hazardous outside country)
Hazardous waste outside country
Identifies the waste treatment operation (recovery or disposal). Required unless confidentiality is claimed.
Destined for recovery
Quantity [t/year]. Required unless confidentiality is claimed
2.62 t/year
Measurement
Identifies the type of method used (CEN/ISO, ETS, etc.). Notice that the method type “WEIGH” (i.e. weighing) only is allowed for waste transfer.
Weighing
Identifies the type of waste (non-hazardous, hazardous within country and hazardous outside country)
Hazardous waste outside country
Identifies the waste treatment operation (recovery or disposal). Required unless confidentiality is claimed.
Destined for recovery
Quantity [t/year]. Required unless confidentiality is claimed
0.42 t/year
Measurement
Identifies the type of method used (CEN/ISO, ETS, etc.). Notice that the method type “WEIGH” (i.e. weighing) only is allowed for waste transfer.
Other measurement/calculation methodology
A short designation or description of the method used. Required for some method types as indicated in the list of legal method type codes.
Vaganje
Identifies the type of waste (non-hazardous, hazardous within country and hazardous outside country)
Hazardous waste outside country
Identifies the waste treatment operation (recovery or disposal). Required unless confidentiality is claimed.
Destined for recovery
Quantity [t/year]. Required unless confidentiality is claimed
0.62 t/year
Measurement
Identifies the type of method used (CEN/ISO, ETS, etc.). Notice that the method type “WEIGH” (i.e. weighing) only is allowed for waste transfer.
Weighing
Pollutant Transfer: